Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T18CM04874
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/24/2018 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* STILL NEED TO REPLACE HOLD DOWN WITH ALTERNATE AT GARAGE | |
07/23/2018 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1. NAIL 1 STUD AND SHINERS AREA IN REAR GARAGE SHEARWALL. 2. INSTALL ALT H.D. IN REAR GARAGE SHEARWALL FOR INTERMEDIATES. 3. NAIL TOP OF PANTRY SHEAR. 4. MISSING TOP RSP-4S IN PATIO AREA. 5. NAIL ALL KING STUDS IN FRONT GARAGE SHEAR PANELS. 6. WEST GARAGE SHEAR NEEDS TO BE NAILED ALL THE WAY UP ABOVE HOLD DOWNS. 7. NOTCH TOP PLATES FOR NON-BEARING BOTTOM TRUSS CORDS AT ENTRY AND PATIO. 8. NEED ALT H.D. AT REAR SHEAR FOR INTERMEDIATES. |