Permit: T18CM04821

Parcel: 128060040


Addresses:

6077 E 20TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/22/2018 PLUMBING - FINAL Approved W?H vent corrected, Gas Line at exterior painted. GWest 6-22-2018
06/22/2018 PLUMBING - FINAL Approved
06/21/2018 PLUMBING - FINAL Partial Approval GAT Approved 6-21-2018.
Corrections for water heater:No screws allowed in B-Vent other than Vent connector to B-Vent. No B-Vent to B-Vent connection screws! Clearance to combustibles per manufacturer is 1", OSB and any wood within that required inch must be corrected. Paint the exterior exposed black iron gas piping.