Permit: T18CM04615

Parcel: 133041760


Addresses:

9312 E BELLEVUE ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
07/03/2018 PLUMBING - GAS PRESSURE TEST Approved CLEAR SW GAS
06/29/2018 PLUMBING - GAS PRESSURE TEST Denied PRESSURE AT 8 LBS. PLEASE RE-PRESSURIZE TO 15 LBS SO INSPECTOR KNOWS WHERE IT STARTED.
DO #S 1, 3, AND 5 FROM PREVIOUS CORRECTION LIST.
06/22/2018 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999
1- GAS PRESSURE TEST WAS DOWN, CHECK THE SYSTEM FOR LEAKS.
2- SHALL PROVIDE A GAS BOND ON THE GAS LINE.
3- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR LOCATED IN THE HALLWAYS TO THE BEDROOMS OR AS CLOSE TO THE WATER HEATER AND FURNACE LOCATION.
4- SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT AND AT THE WATER HEATER DRAFT COLLAR AND VENT CONNECTOR.
5- SHALL PROVIDE A OPEN FIXED POSITION METHOD FOR THE FIREPLACE FLU VENT DAMPER.
6- SHALL PROVIDE SEDIMENT TRAPS FOR THE WATER HEATER AND FURNACE GAS SUPPLYS.


*