Permit: T18CM04238

Parcel: 205946340

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T18CM04238

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/24/2018 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/22/2018 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE A WATER TEST ON THE DWV SYSTEM.
2- SHALL PROVIDE THE MINIMUM TRAP ARM DISTANCE FOR THE CLOTHES WASHER TRAP ARM.
3- SHALL PROVIDE A SHIELD PLATE FOR THE 11/2 VENT AT SOLE PLATE.
4- PLANS CALL OUT FOR A 2 INCH VTR FOR THE 2ND FLOOR WATER CLOSET.
5- 11/2 VENT FOR THE 2ND FLOOR WATER CLOSET RUNS HORIZONTAL BELOW THE FLOOD LEVEL RIM OF THE FIXTURE.


*