Permit: T18CM04074

Parcel: 13109004D


Addresses:

5848 E 22ND ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
06/04/2018 PLUMBING - GAS PRESSURE TEST Approved clear sw gas
05/29/2018 PLUMBING - GAS PRESSURE TEST Not ready for Inspection
05/29/2018 PLUMBING - GAS PRESSURE TEST Not ready for Inspection
05/29/2018 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE APPROVED TWO HOLE STRAPS FOR STRAPPING OF THE GAS LINE.
2- SHALL EXTEND THE WATER HEATER AND WALL HEATER 3- FEET ABOVE THE COOLER WHEN LOCATED WITHIN 10 FEET OF THE COOLER.
3- SHALL PROVIDE DOUBLE WALL FLU VENT AND CAP FOR THE WATER HEATER FLU VENT.
4- SHALL PROVIDE POSITIVE PITCH ON THE T & P DRAIN LINE AND REMOVE THE FLEX LINE.
5- SHALL PROVIDE A SEDIMENT TRAP AT THE WATER HEATER.


*