Permit: T18CM04064

Parcel: 122123260


Addresses:

4530 E PIMA ST #6A


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T18CM04064

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/21/2018 PLUMBING - FINAL Approved CLEAR SW GAS
06/19/2018 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR IN BOTH UNITS.

*
06/04/2018 PLUMBING - FINAL Denied COMPLETE ALL ITEMS FROM PREVIOUS INSPECTION PROVIDE GAS TEST TO MIN 10 PSI
05/25/2018 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL CONNECT THE WATER HEATER VENT CONNECTOR WITH (3) SHEET METAL SCREWS PER JOINT AND AT THE DRAFT COLLAR.
2- SHALL PROVIDE A MINIMUM OF 1-INCH CLEARANCE AROUND THE DOUBLE WALL FLU VENT THROUGH THE CEILING.
3- SHALL REPLACE THE OLD BROKEN T & P DRAIN.
4- SHALL PROVIDE ACCESS TO ALL GAS APPLIANCES IN THE UNITS AT THE TIME OF INSPECTION REQUEST.
5- SHALL RAISE THE FURNACE FLU VENTS 3-FEET ABOVE THE COOLERS.
6- SHALL BOND THE GAS LINE.


*