Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T18CM04064
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2018 | PLUMBING - FINAL | Approved | CLEAR SW GAS | |
06/19/2018 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR IN BOTH UNITS. * |
|
06/04/2018 | PLUMBING - FINAL | Denied | COMPLETE ALL ITEMS FROM PREVIOUS INSPECTION PROVIDE GAS TEST TO MIN 10 PSI | |
05/25/2018 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL CONNECT THE WATER HEATER VENT CONNECTOR WITH (3) SHEET METAL SCREWS PER JOINT AND AT THE DRAFT COLLAR. 2- SHALL PROVIDE A MINIMUM OF 1-INCH CLEARANCE AROUND THE DOUBLE WALL FLU VENT THROUGH THE CEILING. 3- SHALL REPLACE THE OLD BROKEN T & P DRAIN. 4- SHALL PROVIDE ACCESS TO ALL GAS APPLIANCES IN THE UNITS AT THE TIME OF INSPECTION REQUEST. 5- SHALL RAISE THE FURNACE FLU VENTS 3-FEET ABOVE THE COOLERS. 6- SHALL BOND THE GAS LINE. * |