Permit: T18CM04057

Parcel: 205945630

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T18CM04057

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/10/2018 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/08/2018 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1- ALL PLUMBING CORRECTIONS HAVE BEEN MADE.
2- SHALL PROVIDE (3) SIDED BLOCKING ON FORCED AIR VENT IN ENTRY HALL WAY AS REQUESTED.
3- SHALL RELOCATE THE DOMESTIC WATER LINES NO CLOSER THAN 12 INCHES FROM CAN LIGHT IN DINING ROOM.
08/07/2018 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE A WATER TEST ON THE DWV SYSTEM.
2- SHALL MAKE CORRECTIONS FROM PREVIOUS INSPECTION ON 08/06/18


*
08/06/2018 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999
1- 2ND FLOOR TUB TRAP ARM DISTANCE DOES NOT MEET THE MINIMUM TRAP ARM DISTANCE OF (2) TIMES THE PIPE SIZE.
2- 2ND FLOOR GARDEN TUB AND SHOWER HORIZONTAL VENT SHALL RISE VERTICALLY 6 INCHES ABOVE THE FLOOD LEVEL RIM OF THE TUB.


*