Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/26/2018 |
PLUMBING - ROUGH, SOIL |
|
Approved |
|
| 06/25/2018 |
PLUMBING - ROUGH, SOIL |
|
Denied |
10' WATER TEST REQUIRED. NO WATER IN HEAD PIPE |
| 06/22/2018 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection :* |
| 06/21/2018 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
|