Permit: T18CM03838

Parcel: 136383030


Addresses:

4749 S ROSE PL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/16/2018 PLUMBING - INTERMEDIATE Approved
08/15/2018 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999DWV REQUIRES AIR OR WATER TEST. INSTALL A VENT FOR KITCHEN SINK OR USE AN AIR ATTMITTANCE VALVE, SUCH AS "STUDOR" VENT. INSTALL STRAPS TO PROTECT PIPING. SECURE CLOSET FLANGE WITH SCREWS, TO THE FLOOR. INSTALL 2" P TRAP AND RISER FOR WASHER DRAIN. INSTALL HOLDING BRACKETS OR CLAMP BARS FOR PEX PASSING THROUGH WALLS TO ANGLE STOPS. INSTALL CLEAN OUT FOR LAVI WASTE.


*