Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T18CM03544

Parcel: 305972280

Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T18CM03544

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
07/26/2018 SITE - SEWER Approved OK FROM PRIVATE MH#30 TO #36. ANYTHING ELSE NOT SPECIFICALLY NOTED IN PREVIOUS PARTIALS WAS COVERED UP AT TIME OF INSPECTION.
07/24/2018 SITE - SEWER Cancelled IVRS - AP canceled
07/24/2018 SITE - SEWER Cancelled IVRS - AP canceled
07/24/2018 SITE - SEWER Cancelled IVRS - AP canceled
07/16/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH #27 TO #28
07/13/2018 SITE - SEWER Approved OK FROM PRIVATE MH #25 TO #33
07/12/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH #25 TO #32. ALSO OK FROM MH #27 TO #35, HOWEVER THAT SECTION WAS COVERED UP AT TIME OF INSPECTION.
07/06/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH #26 TO #27
07/05/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH #25 TO #26
07/03/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH#24 TO #25
06/29/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH#19 TO #23
06/28/2018 SITE - SEWER Partial Approval IVRS - Inspection :*
06/28/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH# 17 TO #21
06/22/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH #15 TO #17. REQUESTED DRAWINGS AGAIN FROM CONTRACTOR.
06/21/2018 SITE - SEWER Partial Approval 8" OK FROM PRIVATE MH #14 TO #15. DRAWINGS NEED TO BE ONSITE AT TIME OF INSPECTION, OR A COPY OF THE PAGES BEING USED NEED TO BE MADE FOR THE INSPECTOR.
06/20/2018 SITE - SEWER Partial Approval 8" OK BETWEEN PRIVATE MH#13 AND #14
06/19/2018 SITE - SEWER Partial Approval 8" LINE OK BETWEEN PRIVATE MH#5 AND #12
06/15/2018 SITE - SEWER Partial Approval 8" LINE OK BETWEEN PRIVATE MH#4 AND #11.
06/14/2018 SITE - SEWER Partial Approval MAIN OK FROM PRIVATE MH#7 TO MH#8. FROM NOW ON NOTES FOR THE VERTICALS/HCS CONNECT WILL BE UNDER 3055 SWER HCS CONNECT INSPECTION.
06/13/2018 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
06/12/2018 SITE - SEWER Partial Approval MAIN OK FROM PRIVATE MH#7 TO MH#8.
06/11/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH#6 TO MH#7, VERTICALS OK BETWEEEN 5 & 6 ON W. SIDE. MAKE SURE CAPS ARE ON ENDS OF RUNS BEFORE BACKFILL.
06/08/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH#5 TO MH#6.
06/07/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH #4 TO MH#5. LATERALS OK WESTSIDE TO MH#4
06/06/2018 SITE - SEWER Partial Approval OK FROM PRIVATE MH #3 TO PRIVATE MH #4
06/05/2018 SITE - SEWER Partial Approval FROM PRIVATE #1TO #2 OK.
06/04/2018 SITE - SEWER Partial Approval WORKING FROM PRIVATE MH #1 TO #3.
06/01/2018 SITE - SEWER Continued SDR- 35 FROM PUBLIC MH #3 TO PRIVATE MH #1 OK ONLY.