Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/25/2018 | EXT METAL CLIPS/EXT SHEATHING | Approved | Check that all gable ends have reflective or Foil back OSB in attic to living area. GWest 6-25-2018 | |
| 06/22/2018 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | NR, same corrections as prior inspection. | |
| 06/20/2018 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | See your 6-12-2018 corrections | |
| 06/12/2018 | EXT METAL CLIPS/EXT SHEATHING | Denied | 3. NAIL WALL OSB INTO BOTH HOLD DOWN STUDS ALL THE WAY UP WALL. 4. OSB NOT NAILED UNDER S.W. BEDROOM WINDOW. 5. ALL BEDROOM WINDOW SILLS HAVE A MAX SILL HEIGHT OF 44". THE WINDOW OPENING SHOULD BE NO HIGHER THAN 44" |