Date Description Inspector Results Comments
06/13/2018 EXT METAL CLIPS/EXT SHEATHING Approved
06/12/2018 EXT METAL CLIPS/EXT SHEATHING Partial Approval GABLE BRACING NEEDS A34 CLIPS AND BRACING NEEDS TO BE AT MIN. 40 DEGREE ANGLE PER DETAIL 408. MISSING H3 CLIPS AT PATIO PER DETAIL 334.