Permit: T18CM02601

Parcel: 110080180


Addresses:

2701 N GOYETTE AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/25/2018 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
04/23/2018 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL RELOCATE THE OVERHEAD WATER LINES NO CLOSER THAN 12 INCHES FROM THE CAN LIGHTS IN THE KITCHEN.
2- SHALL LOCATE THE OUTLET OF THE VENT ABOVE THE CENTER LINE OF THE DRAIN FOR THE SHOWER IN THE DEN RESTROOM.
3- SHALL PROVIDE A MINIMUM OF A #8 GREEN TRACER WIRE ON THE ENTIRE BLDG. SEWER.
4- SHALL CONNECT THE BLDG. SEWER TO THE HCS AT THE PROPERTY LINE.
5- SHALL PROVIDE A MINIMUM OF 12 INCHES OF COVER ON THE BLDG. SEWER.
6- SHALL LOCATE THE VENT FOR THE CLOTHES WASHER ON THE DRAIN AND NOT THE STAND PIPE WITH A DIRECTIONAL FITTING.
7- SHALL INSTALL THE UNDERGROUND PLUMBING IN THE NEW BATHROOM AS PER THE BATHRROM GROUP REQUIREMENTS OR INSTALL A CONVENTIONAL ROUGH IN.
9- SHALL PROVIDE THE WIDE 4 INCHE SAFTEY PLATES ON TOP AND SOLE PLATES WHERE THERE IS SANITARY VENTS.
10 SHALL LOCATE THE VENT FOR THE KITCHEN SINK ABOVE THE TRAP ARM.


*