Permit: T18CM02548

Parcel: 13012224B


Addresses:

3658 E 32ND ST

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
06/27/2018 BUILDING PRE-SLAB Approved
06/22/2018 BUILDING PRE-SLAB Correction Required Sleeve ABS through structural masonry footing for structural support. All ABS DWV plumbing requires slope to drain, level out Closet Flange. 10 foot head of water or air test required for DWV testing. All rebar to have min 3" separation from earth/dirt. Slab grade reinforcement OK to be 2" above dirt. Clean up the work area so as not to be a harzard for workers and inspectors. Existing slabs/concrete that will be in the new pour shall not compromise the ne work and concrete being poured.
Finish corrections and recall inspection.