Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T18CM02217
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/27/2018 | FRAMING | Approved | ||
06/25/2018 | FRAMING | Denied | 1. REPAIR ALL TORN TAR PAPER. 2. NEED BANG PLATES AT: TOP OF HOMERUNS, STUD AT WEST LIVING ROOM WALL, TOP PLATES AT PATIO DOOR. 3. CORRECT OVER NOTCHED STUD IN REAR GARAGE WALL. 4. FHA STRAPS, ON PLUMBING TOP PLATE OVERBORES, NEED AT LEAST 10D COMMON NAILS, - NOT ROOFING NAILS. 5. STITCH BOWED STUD UNDER FRONT GARAGE GLUELAM - NORTH END. 6. STRAP A/C TRUNK LINE UP, IN FRONT 1ST FLOOR ROOM. 7. FHA STRAP BACK SIDE OF ABS TOP PLATES IN 1ST FLOOR FRONT ROOM. 8. STRAP NON-CABIN TIED TOP PLATES AT 45 DEGREE WALL AT GARAGE MAN DOOR. 9. FIRE STOP STOVE VENT AT 8'. 10. SHIM TOP OF STAIR STRINGERS. 11. MOVE PEX OFF LIGHT ABOVE ISLAND. STOPPED INSPECTION AFTER 1ST FLOOR. |