Permit: T18CM01742

Parcel: 122060240


Addresses:

4205 E WAVERLY ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/20/2018 PLUMBING - GAS PRESSURE TEST Approved
04/04/2018 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL SECURE THE GAS LINE THAT SERVES THE WATER CLOSET AND DRYER.
2- SHALL PROVIDE THE FLEX CONNECTOR FOR THE GAS PACK ON THE ROOF.
3 SHALL SEAL ALL ROOF JACKS.
4- SHALL PROVIDE A GAS BOND ON THE SYSTEM.
5- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR AND LOCATE NEAR THE APPLIANCES AND AS PER MANUFACTURERS INSTALLATION STANDARDS.
6- SHALL PROVIDE OR EXTEND THE DBL WALL FLU VENT THRU THE CEILING MIN OF 1 INCH BELOW THE CEILING THEN CONNECT THE SINGLE WALL VENT CONNECTOR WITH (3) SHEET METAL SCREWS PER JOINT AND DRAFT COLLAR.
7- SHALL EXTEND THE T & P DRAIN TO DAYLIGHT AND TERMINATE 6 INCHES ABIVE SUB GRADE.


*