Permit: T18CM01647

Parcel: 126062410


Addresses:

826 N IRVING CI

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/21/2018 PLUMBING - FINAL Approved IVRS - Inspection :*
CLEAR GAS METER
03/06/2018 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999
1- GAS PRESSURE TEST PROVIDED.
2- SHALL PROVIDE GAS BOND TO THE SYSTEM.
3- SHALL EXTEND THE FURNACE FLU VENT A MINIMUM OF 3 FEET ABOVE THE COOLER WHEN THE B-VENT IS LOCATED WITHIN 10 FEET OF THE COOLER.
4- SHALL EXTEND THE WATER FLU VENT 2 FEET ABOVE THE COOLER WHEN THE B-VENT IS LOCATED WITHIN 10 FEET OF THE COOLER.

*