Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T18CM01329
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/27/2018 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
04/25/2018 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL LOCATE THE ACCESSIBLE WATER CLOSET 16 TO 18 INCHES FROM SIDE WALL CLEARANCE TO THE CENTER OF THE WATER CLOSET. 2- SHALL PROVIDE INSULATION ON THE CONDENSATE DRAIN. 3-ACCESSIBLE LAVATORY RIM HEIGHT FROM FINISH FLOOR SHALL BE 34 INCHES MAX. * |