Permit: T18CM01070

Parcel: 133040550


Addresses:

9140 E BELLEVUE ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/08/2018 FRAMING Approved IVRS - Inspection :*
04/27/2018 FRAMING Partial Approval IVRS - Inspection :*
1- SHALL SEAL ALL TOP PLATE PENETRATIONS WITH FIRE RATED FOAM OR CUALKING.
2- SHALL PROVIDE THE WIDE SHIELDED PLATES ON ALL TOP AND SOLE PLATE THAT HAVE A VTR WITHIN 11/2 INCHES FROM THE EDGE OF STUD.
3- SHALL PROVIDE A DOUBLE FIXTURE FITTING FOR THE DOUBLE LAVATORYS DRAINS.
4- SHALL PROVIDE A WATER TEST ON THE DWV SYSTEM TO THE TOP OF VTR.