Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - PROGRESS
Permit Number - T18CM01003
Inspection Description - BUILDING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/23/2018 | BUILDING - PROGRESS | Approved | ||
02/21/2018 | BUILDING - PROGRESS | Denied | Note: All work was covered prior to any inspections. Expose portions of the footing, bottom plates, anchor bolts, H2.5s, loose water tubing in walls, electrical wiring, and building sewer piping and tie-in. Provide an air test on DWV or expose for water test. Provide access to attic, duct connections, and roof. Pvc is not approved for hot water in the building. Galvanized may not touch copper. Grounding conductor is improperly spliced. Panel is not addressed. Stucco is not per plan, no foam, also has cracks and damage around windows. Seal windows as required. Install hose thread vacuum breakers. Plug abandon sink drain near wh. |