Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 11/20/2019 |
MECHANICAL - INTERMEDIATE |
|
Approved |
|
| 10/31/2019 |
MECHANICAL - INTERMEDIATE |
|
Partial Approval |
Truss drawing do not match. Different manufacturers. Fire caulk around dryer duct. Secure toilet flanges to floor. Missing insulation behind Tub/shower in master bedroom. Plumbing pipe in attic is back pitched. Fill DWV with water. Missing make-up/fresh-air ventilation. See notes on mechanical plan. |
| 10/09/2019 |
MECHANICAL - INTERMEDIATE |
|
Denied |
Support duct vents on three sides, condensate line needs to pitch. Protect line set at sole plate. Complete condensate line at garage. Remove vent from attic access. STOPPED INSPECTION. |