Permit: T18CM00895

Parcel: 125170620


Addresses:

3838 E CALLE CORTEZ

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/08/2018 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :* ATTACH CLOSET FLANGES TO CONCRETE SLAB
08/01/2018 PLUMBING - INTERMEDIATE Denied 1- CAN NOT HAVE TWO P-TRAPS SERVING ONE TRAP ARM AT LAVATORIES.
2- SHALL PROVIDE THE REQUIRED SHIELD PLATES ON THE SOLE AND TOP PLATES TO PROTECT THE ABS WASTE AND VENTS WERE NEEDED.
3- WATER LINE SHALL NOT BE LOCATED LES THAN 12 INCHES. FROM CAN LIGHTS BY SHOWER.
4- SHALL INSTALL THE CLOSET RINGS.