Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2018 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 02/08/2018 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL EXTEND THE FURNACE FLU VENT AND TERMINATE IT 3 FEET ABOVE THE COOLER WHEN LOCATED WITHIN 10 FEET OF COOLER. 2- SHALL SEAL ALL EXTERIOR GAS LINE PENETRATIONS THRU WALLS.. 3- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR LOCATED IN THE HALLWAY TO THE BEDROOMS. 4- SHALL BOND THE GAS LINE OR HARD PIPE INTO THE FURNANCE. 5- SHALL PROVIDE A DAMPER KIT AND TO INSTALLED IN A FIXED OPEN POSITION FOR BOTH FIREPLACES. 6- RETEST THE SYSTEM. 7- SHALL PROVIDE A APPROVED DRAWING ON THE GAS SYSTEM. * |