Permit: T18CM00407

Parcel: 122020220


Addresses:

2310 N MADELYN CI

Inspection Status: Denied

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
04/20/2018 BUILDING - FINAL Denied 1. CANNOT FINAL BUILDING UNTIL ALL ISSUES HAVE BEEN ADRESSED.
2. ELECTRIC OUTLETS THAT ARE WITHIN ASINK AND OR WATER FAUCET MUST HAVE BUILT IN GFI (GROUND FAULT CIRCUIT INTERRUPTERS) AS PER CODE, ALL RECEPTICLES SERVING COUNTERTOP AREAS AND ANY RECEPTICLE WITHIN 6FT OF SINK. ALSO RECEPTICLE SUPPLYING A DISH WASHER. THIS ALSO INCLUDES BATHROOMS OF WICH HAVE BEEN INSPECTED THREE TIMES AND STILL HAVE NOT BEEN BROUGHT UP TO CODE.
04/19/2018 BUILDING - FINAL Cancelled
04/19/2018 BUILDING - FINAL Approved
04/17/2018 BUILDING - FINAL Denied NO ANTI TIP ON STOVE
NO CATCH PAN UNDER WATER HEATER OR SEDIMENT TRAP
SMOKE DETECTORS B/O
ELEC. GFI ALL OVER HOUSE B /O
STOPPED INSPECTION AT THIS POINT
04/05/2018 BUILDING - FINAL Denied WATER LINE TO DISPOSAL HAS TO BE ABOVE GARBAGE DISPOSAL, TIED UP TO BOTTOM OF SINK
ALL ELECTRICALM G.F.I DO NOT WORK SET ON OPEN GROUND
SMOKE DETECTORS B/O
STOP INSPECTION AT THIS POINT