Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T18CM00171
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/24/2018 | PLUMBING - INTERMEDIATE | Approved | ||
06/19/2018 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE A C.O. AT THE BASE OF THE SOIL STACK. 2- SHALL PROVIDE A MINIMUM OF 18 INCHES AND MAX 42 INCHES OF STAND PIPE FOR THE CLOTHES WASHER. 3- SHALL PROVIDE SEPARATE WASTE LINES FOR THE GRAY WATER SYSTEM. 4- SHALL INSTALL THE 2ND FLOOR SOIL SYSTEM PER THE APPROVED IPC HORIZONTAL WASTE AND VENT SYSTEM REQUIREMENTS. 5 RETEST THE SYSTEM. * |