Permit: T18CM00128

Parcel: 122154170


Addresses:

3417 E PIMA ST


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T18CM00128

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/08/2018 PLUMBING - INTERMEDIATE Approved
05/04/2018 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999


*
05/02/2018 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1- SHALL PROVIDE (3) SIDED BLOCKING ON ALL FORCED AIR VENTS.
2- SHALL SEAL ALL TOP PLATE PENETRATIONS WITH FIRE RATED CUALK OR FOAM.
3- SHALL PROVIDE A T & P DRAIN AT THE WATER HEATER.
4- SHALL PROVIDE A SEPARATE TRAP ARM FOR THE DBL. LAVATORY. ONLY ONE TRAP MAY BE SERVED ON A TRAP ARM.