Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T18CM00128
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/08/2018 | PLUMBING - INTERMEDIATE | Approved | ||
05/04/2018 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999 * |
|
05/02/2018 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1- SHALL PROVIDE (3) SIDED BLOCKING ON ALL FORCED AIR VENTS. 2- SHALL SEAL ALL TOP PLATE PENETRATIONS WITH FIRE RATED CUALK OR FOAM. 3- SHALL PROVIDE A T & P DRAIN AT THE WATER HEATER. 4- SHALL PROVIDE A SEPARATE TRAP ARM FOR THE DBL. LAVATORY. ONLY ONE TRAP MAY BE SERVED ON A TRAP ARM. |