Permit: T18BU00242

Parcel: 14043013D


Addresses:

1400 E AERO PARK BL


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T18BU00242

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
08/24/2018 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
08/22/2018 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL TOP OUT 150'
NORTH WALL 2ND LIFT 120'
EAST WALL 2ND LIFT 10'
08/20/2018 REINFORCED MASONRY PRE-GROUT Partial Approval LOOKED AT 300 FEET CENTER SECTION OF THE NORTH WALL FOR THE PRE-GROUT FOR THE 2ND COURSE.
08/17/2018 REINFORCED MASONRY PRE-GROUT Partial Approval NORTH WALL 2ND LIFT 150' ONLY
08/16/2018 REINFORCED MASONRY PRE-GROUT Partial Approval TOP OUT WEST WALL
08/15/2018 REINFORCED MASONRY PRE-GROUT Partial Approval 1st lift north wall ok
08/14/2018 REINFORCED MASONRY PRE-GROUT Partial Approval 2nd lift west wall ok
08/10/2018 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT SOUTH WALL PENDING RFI AT CONTROL JOINTS EVERY 90' EJC TO MEJ
SEE RFI #13
08/08/2018 REINFORCED MASONRY PRE-GROUT Partial Approval TOP OUT SOUTH WALL FROM 2ND STEP DOWN TO 3RD STEP DOWN
2ND LIFT SOUTH WALL
08/06/2018 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
08/03/2018 REINFORCED MASONRY PRE-GROUT Partial Approval TOP OUT SOUTH WALL FROM SE CORNER TO 2ND STEP DOWN
2ND LIFT 120' SOUTH WALL FROM 2ND STEP DOWNT TO WEST
08/02/2018 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT WEST WALL
1ST LIFT NORTH WALL FROM NW CORNER TO 60' EAST
07/31/2018 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT EAST WALL
SOUTH WALL FROM SE CORNER 1ST STEP DOWN TO 2ND STEP DOWN2ND LIFT ONLY
1ST LIFT SOUTH WALL
07/27/2018 REINFORCED MASONRY PRE-GROUT Partial Approval EAST WALL TOP OUT TO 5TH EXPANSION JOINT FROM NE CORNER
EASR WALL 2ND LIFT FROM 5TH EXPANSION JOISNT TO SE CORNER
SOUTH WALL FROM SE CORNER TO 2ND EXPANSION JPINT2ND LIFT
07/25/2018 REINFORCED MASONRY PRE-GROUT Partial Approval 2ND LIFT EAST WALL FROM NE CORNER TO 5TH EXPANSION JOINT FROM SE CORNER
111' SOUTH WALL 1ST LIFT FROM LAST INSPECTION TO 30' FROM WEST CORNER
07/23/2018 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
07/20/2018 REINFORCED MASONRY PRE-GROUT Continued LOOKED AT THE MASONRY WALL FOR THE FIRST LAYER FOR THE EAST AND AND THE EAST HALF OF THE SOUTHWALL. OK TO PLACE THE GROUT AT THIS TIME.
07/19/2018 REINFORCED MASONRY PRE-GROUT Not ready for Inspection MISSING VERTS AT THIS TIME EAST WALL 1ST LIFT