Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - ENGR - Signage Final
Permit Number - T17OT01153
Inspection Description - COT - ENGR - Signage Final
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/19/2018 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - Case documentation completed for building official appeal. |
01/24/2018 | COT - ENGR - Signage Final | hthrall | Approved | Entered by HTHRALL1 - Building Official response issued per Chapter 3-107.C. (Sign Code). Take sign height from grade at base of monument closest to Carondelet (20' setback from curb) in review of 3-33 Grade. Records updated, contractor emailed copy of documents. |
01/17/2018 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - Case entry for building official response completed. |
01/12/2018 | COT - ENGR - Signage Final | HTHRALL | Continued | Entered by HTHRALL1 - MONUMENT SIGN REVISION SUBMITTED. PACKAGE INCLUDES BUILDING OFFICIAL APPEAL. APPEAL REQUESTS TO DETERMINE SIGN GRADE (DIFFERS FROM ALL STREET SIDES). ADDTL. FEE FOR B.O. APPEAL PROCESSED. |
12/26/2017 | COT - ENGR - Signage Final | hthrall | Approved | Entered by HTHRALL1 - REVISED DRAWINGS APPROVED. |
12/22/2017 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - 12/22/17 - REVISION RECEIVED TO REDUCE FREESTANDING SIGN HEIGHT. |
12/20/2017 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - PER INSPECTION BY DAVID ROBERTS VIA LASER ON 12/20/17: PROPOSED SIGN BASE TO TOP OF CARONDELET STREET CURB IS 1.79 FEET HIGHER. SIGN WILL BE IN COMPLIANCE WITH MAXIMUM 10' HEIGHT AS TAKEN FROM TOP OF CARONDELET STREET CURB. SIGN GRADE AT BASE TO TOP OF WILMOT IS 3.09 FEET TALLER THAN CURB OF WILMOT. SIGN WILL EXCEED MONUMENT SIGN HEIGHT ALLOWANCE AS TAKEN FROM TOP OF WILMOT CURB. PER 3-107, AND SIGN CODE ADMINISTRATION AND BUILDING OFFICIAL CONCURRENCE - AN APPEAL TO BUILDING OFFICIAL IS ALLOWED DUE TO THE UPHILL SLOPE FROM THE ROADWAY TO MEASURE SIGN AT GRADE AT BASE. CONTRACTOR PROVIDED WITH FORM. |
12/20/2017 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - Letter of architectural approval received from St. Joseph's campus at 10:30 a.m. Conducting site grade/setback check with laser survey. |
12/19/2017 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - REGARDING WALL SIGNS - NO CHANGES/OK. REGARDING FREESTANDING SIGN: CONFIRMED ONE CAISSON FOOTER, OFF-SET, ON DRAWINGS, IS DEFINITE. CONTACTED CONTRACTOR TO REQUEST REVISED ENGINEERING FOR OFF-SET POLE MOUNT. |
12/20/2017 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - REGARDING FREESTANDING SIGN: REVISED ENGINEERING RECEIVED FROM CONTRACTOR 7 A.M. FOR OFF-SET "FLAG MOUNT" POLE/FOOTER INSTALL. (STRUCTURAL REVIEWER REVIEWED/APPROVED NEW FOOTER DIAGRAMS/ENGINEERED CALCS 8:00 A.M.) AWAITING LETTER FROM ST. JOSEPH'S FOR ARCHITECTURAL APPROVAL OF SIGN DESIGN. CONDUCTING SITE GRADE/SETBACK CHECK VIA LASER AND EVALUATE UPON REVIEWING MEASUREMENTS. |
12/19/2017 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - REVISED SUBMITTAL RECEIVED FOR REVIEW (OF WALL SIGNS AND 1 FREESTANDING SIGN AT SOUTH SIDE OF PREMISES). REQUIRES SITE GRADE/SETBACK INSPECTION. |
11/07/2017 | COT - ENGR - Signage Final | hthrall | Correction Required | Entered by HTHRALL1 - RE: WALL SIGNS & REPLACEMENT FREESTANDING SIGN FOR: ST. JOSEPH'S HOSPITAL / 350 N WILMOT RD PERMIT: T17OT01153 REVIEWER: H.THRALL / R. WELLS DATE: 11/07/17 DEVELOPMENT ZONING - PAD-13 1) PROVIDE SIGN AREA BASED ON CABINET. DIMENSIONS ON PLAN INDICATES CLASSIFICATION OF LOW-PROFILE SIGN. PROVIDE 2' TALL BASE FULL LENGTH UNDER THE SIGN PER 3-61.B.5. 2) APPEARS SLOPE ON SITE AT SIGN BASE, AND PLANS SHOW SIGN HEIGHT MEASURED FROM GRADE AT SIGN BASE. PER 3-33 AND PRIOR SIGN DETERMINATION, SIGN HEIGHT TO BE MEASURED PER TOP OF STREET CURBS TO TOP OF SIGN CABINET, NOT TO EXCEED 8 FEET FOR A LOW PROFILE SIGN. PROVIDE MEASUREMENT DIFFERENCE BETWEEN TOP OF CARONDELET AND TOP OF WILMOT CURBS TO THE GRADE AT SIGN BASE AND NOTE HEIGHT ADJUSTMENT ACCORDINGLY. 3) ACKNOWLEDGED TWO SETBACKS LISTED. PROVIDE SETBACK DIMENSION FROM EAST LEADING EDGE OF SIGN STRUCTURE TO CARONDELET FACE OF CURB (PER 3-61) (THE CLOSEST PART OF THE SIGN TO THE STREET). 4) PROVIDE LETTER FROM ST. JOSEPH'S ARCHITECTURAL REVIEW BOARD (ARB) APPROVING SIGNAGE. PER PAD-13 ZONING DOCUMENT, PAGE 52. (NOTE - PAGES 49-51 INFER A PLANNED UNIFORM SIGN PACKAGE.) REGARDING WALL SIGNS - A) Per Eric Newcomb, special inspections for sign height off ground can be waived for pan channel lettering/logo, suffice mount. |
11/04/2022 | COT - ENGR - Signage Final | Canceled | Inspection Canceled |