Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T17DV05273
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/17/2017 | INSP - INITIAL CODE ENFORCMENT | Approved | THE AIR CONDITIONING THE DISCONNECTING MEANS FOR THE AIR CONDITIONING UNIT ARE LOCATED INSIDE THE UTILITY ROOMS FOR ALL UNITS IN BUILDING 2 THE EQUIPMENT DISCONNECTS ARE NOT IN SIGHT VISIBILITY. THE AIR CONDITIONING CONDENSERS LOCATED AT BUILDING 2 UNIT'S 2103 AND 2101 HAVE BEEN INSTALLED ON THE GROUND. THESE UNITS DO NOT MEET THE CLEARANCE OR INSTALL REQUIREMENTS. THE GROUNDING ELECTRODE CONDUCTORS HAVE BEEN CUT AT BOTH SERVICES LOCATED AT BUILDING 8. THERE HAS BEEN AN IRON FRAMED ASSEMBLY WITH NO DOORS INSTALLED AT THE END OF EACH SIDE OF THE BUILDING'S CORRIDOR. THIS ASSEMBLY WOULD CONTROL EGRESS. THE ASSEMBLY IS NOT FINISHED AT THIS TIME. THIS ASSEMBLY IN LOCATED AT BUILDING 2 BUILDING 1 EASTSIDE SERVICE, THE MAIN DISCONNECTS FOR EACH UNITS ARE NOT PROPERLY LABELED WESTSIDE SERVICE, THE MAIN DISCONNECTS FOR EACH UNITS ARE NOT PROPERLY LABELED. MISSING DEAD FRONT ON THE POOL EQUIPMENT DISCONNECT UNUSED OPENINGS MISSING CLAMP TO THE TO OVER HEAD RISER BUILDING 2 THE NORTHSIDE SERVICE GROUNDING ELECTRODE CONDUCTED IS NOT PROPERLY SECURED TO THE BUILDING MISSING HARDWARE AT THE SERVICE EQUIPMENT REPLACE DECK BOARDS AS NEEDED THE SOUTHSIDE SERVICE, MAIN DISCONNECTS FOR EACH UNITS ARE NOT PROPERLY LABELED MISSING CLAMP ON OVER HEAD RISER GUTTER BOX UNUSED OPENINGS ALL EXTERIOR LIGHT FIXTURES ARE NOT CODE COMPLIANT UNIT 2103 THE GAS FURNACE HAS THE EXHAUST VENT PIPE DISCONNECTED FROM THE FURNACE. WATER HEATER HAS NO DISCHARGE PIPE A/C DISCONNECT NOT CODE COMPLIANT DRYWALL REPAIR REQUIRED IN UTILITY ROOM UNIT 2104 COLD WATER SHUT OFF MISSING HANDLE ON WATER HEATER MISSING EXHAUST VENT PIPE TO GAS FURNACE DRYWALL REPAIR REQUIRED IN UTILITY ROOM UNIT 2208 COLD WATER SHUT OFF MISSING HANDLE ON WATER HEATER WATER HEATER HAS NO DISCHARGE PIPE DRYWALL REPAIR REQUIRED IN UTILITY ROOM UNIT 2207 A/C DISCONNECT NOT CODE COMPLIANT DRYWALL REPAIR REQUIRED IN UTILITY ROOM WATER HEATER HAS NO DISCHARGE PIPE NOT CODE COMPLAINT. UNIT 2102 LIGHT FIXTURE WALL PLATE HAS DETACHED FROM THE BUILDING, EXPOSED WIRES CONDENSATE LINE NOT PLUMBED OUT THE BUILDING A/C DISCONNECT NOT CODE COMPLAINT DRYWALL REPAIR REQUIRED IN UTILITY ROOM WATER HEATER HAS NO DISCHARGE PIPE UNIT 2206 A/C DISCONNECT NOT CODE COMPLAINT DRYWALL REPAIR REQUIRED IN UTILITY ROOM WATER HEATER HAS NO DISCHARGE PIPE CONDENSATE LINE NOT PLUMBED OUT THE BUILDING DRYWALL REPAIR REQUIRED IN UTILITY ROOM UNIT 2101 A/C DISCONNECT NOT CODE COMPLAINT DRYWALL REPAIR REQUIRED IN UTILITY ROOM WATER HEATER HAS NO DISCHARGE PIPE NOT CODE COMPLAINT. CONDENSATE LINE NOT CODE COMPLAINT DRYWALL REPAIR REQUIRED IN UTILITY ROOM WALL MOUNTED LIGHT FIXTURE HAS EXPOSED WIRING UNIT 2205 A/C DISCONNECT NOT CODE COMPLAINT DRYWALL REPAIR REQUIRED IN UTILITY ROOM WATER HEATER HAS NO DISCHARGE PIPE BUILDING 3 THE EASTSIDE SERVICE GROUNDING ELECTRODE CONDUCTOR IS NOT PROPERLY SECURED TO THE BUILDING GUTTER BOX MISSING HARDWARE. BUILDING 4 THE SERVICE GROUNDING ELECTRODE CONDUCTOR IS NOT PROPERLY SECURED TO THE BUILDING THE CLAMP TO THE OVERHEAD RISER IS MISSING BUILDING 5 THE WESTSIDE SERVICE, MAIN DISCONNECTS FOR EACH UNITS ARE NOT PROPERLY LABELED BUILDING 6 THE WEST SIDE 4 METERED PACK HAS MISSING MAIN BREAKER COVERS THE EASTSIDE SERVICE, MAIN DISCONNECTS FOR EACH UNITS ARE NOT PROPERLY LABELED THE CLAMP TO THE OVERHEAD RISER IS MISSING UNUSED OPENINGS IN THE GUTTER BOX BUILDING 7 THE WESTSIDE SERVICE, MAIN DISCONNECTS FOR EACH UNITS ARE NOT PROPERLY LABELED THE EASTSIDE SERVICE, MAIN DISCONNECTS FOR EACH UNITS ARE NOT PROPERLY LABELED THE GROUNDING ELECTRODE CONDUCTOR IS NOT SECURED TO THE BUILDING BUILDING 8 THE WESTSIDE SERVICE, MAIN DISCONNECTS FOR EACH UNITS ARE NOT PROPERLY LABELED |