Case: T17DV03799

Parcel: 118040030

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
08/18/2017 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CALL OUT BY TFD: HOUSE FIRE: THE REAR ATTACHED ENCLOSED PATIO HAD FIRE DAMAGE TO THE EXTERIOR WOOD SIDING AND (6) 2 X 6 RAFTERS, ROOF SHEATHING DAMAGE ONLY AT THE EAVE AREA. THERE IS A 4 X 6 BEAM ALSO HAS FIRE DAMAGE TO AN AREA OF ABOUT 2 FEET, THERE IS INTERIOR DAMAGE TO THE SOUTH WALLS WOOD PANELING AND ONE 4 X 4 WINDOW. THE INTERIOR IS UNSANITARY AND FOUND EXTENSION CORDS USED AS PERMANENT WIRING IN THE ENCLOSED PATIO AREA. THE MAIN DISCONNECT HAS NO METER.
THERE IS TWO ROMEX CABLES NUMBER 12 WHICH HAVE BEEN SPLICED INTO THE SERVICE DROP LOCATED ON THE ROOF. THESE CABLES RUN DOWN TO THE SIDE OF THE DISCONNECT WHICH HAS TWO HOLES WHICH HAVE BEEN DRILLED INTO THE DISCONNECTS BODY. THE CABLES ENTER HERE AND CONNECTED TO THE 100 AMP MAIN BREAKER.. THE CONNECTION POINT OF THE CABLES TO THE MAIN BREAKER HAS BURNT AND CORROSION TO THE CABLES SHEATHING.
THIS TAMPERING WAS REPORTED TO TEP, SOON AFTER TEP DID CUT POWER AT THE POLE. THE DWELLING WAS CONDEMNED UNFIT TO OCCUPY. PERMITS REQUIRED FOR ALL REPAIRS