Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2017 | INSP - INITIAL CODE ENFORCMENT | Approved | UNIT B UNIT B HAS MULTIPLE NON GROUNDING TYPE RECEPTACLES WHICH HAVE BEEN REPLACED WITH GROUNDING TYPE RECEPTACLES IN THE INTERIOR OF THE DWELLING. ALL INTERIOR RECEPTACLES ARE LOOSE AND SOME ARE INOPERABLE MULTIPLE OUTLETS HAVE MISSING COVER PLATES THE REAR EXTERIOR DUPLEX RECEPTACLE HAS OPEN GROUND THE NEW 125 AMP MAIN DISCONNECT FOR UNIT INSTALLED WITHOUT PERMIT DRAIN PIPES UNDER THE KITCHEN SINK LEAK NO SMOKE DETECTORS IN BEDROOMS CEILING LIGHT FIXTURES IN BATHROOM AND BEDROOM HAVE THE GLOBES FRONT PORCH BEAM HAS WOOD ROT (REPLACE) PERMIT BATHROOM PEDESTAL SINK IN LOOSE. GAS WATER HEATER: MISSING DISCHARGE PIPE NOT PROPERLY INSTALLED NO ENCLOSURE EXHAUST VENT PIPE ZERO CLEARANCE FROM WOOD ROOF DECKING UNIT 'S A AND B THERE ARE TWO ROOF MOUNTED HVAC UNITS THAT HAVE BEEN INSTALLED WITHOUT PERMITS. VERIFY GROUNDING SYSTEM A KNOCK OUT OPENING IS BEING USED FOR THE GROUNDING ELECTRODE CONDUCTOR UNIT A THE MAIN DISCONNECT FOR UNIT A HAS UNUSED OPENINGS NO LABELING GAS WATER HEATER; " LEAKS " NO GAS SHUT OFF " BODY HAS RUST " NO DISCHARGE PIPE " NO ENCLOSURE T15CM06941 GAS PERMIT NOT FINAL AND IS EXPIRED |