Case: T17DV03410

Parcel: 130151700


Addresses:

4526 E SYLVANE ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
08/09/2017 INSP - INITIAL CODE ENFORCMENT Approved MAIN ELECTRICAL SERVICE PANEL HAS NEUTRALS AND GROUND CONNECTED ON THE SAME BUS BARS.
BREAKERS ARE MISLABELED, SPECIFICALLY 15 AMP BREAKER LABELED LIVING ROOM POWERS THE SOUTH BEDROOM AND THE SOUTH OUTLET IN THE KITCHEN.
COUNTER OUTLET LEFT OF STOVE IS NOT GFCI PROTECTED.
OUTLET ON SOUTH END OF THE KITCHEN COUNTER IS NOT GFCI PROTECTED.
STOVE VENTING SYSTEM HAS BEEN REMOVED.
BATHTUB WALL JOINTS ARE NOT PROPERLY SEALED ALLOWING WATER TO ENTER THE WALL.
ADDITION DRYWALL AT BASE IS BROKEN/MISSING.
ADDITION DOOR IS DETERIORATED/BROKEN AND LACKS AN OPERATIONAL DOOR SWEEP.
ADDITION LAUNDRY ROOM DRY WALL SHOWS SIGNS OF WATER DAMAGE AND DETERIORATION.
EXTERIOR WALLS T1-11 IS DETERIORATED AT THE BASE THROUGHOUT THE ENTIRE ADDITION.