Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2017 | INSP - INITIAL CODE ENFORCMENT | Approved | MAIN ELECTRICAL SERVICE PANEL HAS NEUTRALS AND GROUND CONNECTED ON THE SAME BUS BARS. BREAKERS ARE MISLABELED, SPECIFICALLY 15 AMP BREAKER LABELED LIVING ROOM POWERS THE SOUTH BEDROOM AND THE SOUTH OUTLET IN THE KITCHEN. COUNTER OUTLET LEFT OF STOVE IS NOT GFCI PROTECTED. OUTLET ON SOUTH END OF THE KITCHEN COUNTER IS NOT GFCI PROTECTED. STOVE VENTING SYSTEM HAS BEEN REMOVED. BATHTUB WALL JOINTS ARE NOT PROPERLY SEALED ALLOWING WATER TO ENTER THE WALL. ADDITION DRYWALL AT BASE IS BROKEN/MISSING. ADDITION DOOR IS DETERIORATED/BROKEN AND LACKS AN OPERATIONAL DOOR SWEEP. ADDITION LAUNDRY ROOM DRY WALL SHOWS SIGNS OF WATER DAMAGE AND DETERIORATION. EXTERIOR WALLS T1-11 IS DETERIORATED AT THE BASE THROUGHOUT THE ENTIRE ADDITION. |