Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T17DV03076
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/18/2017 | INSP - INITIAL CODE ENFORCMENT | Approved | INSPECTION DID FIND MULTIPLE AREAS OF THE INTERIOR CEILING DAMAGED BY WATER, EVIDENCED BY SOAKED, DAMAGED DRYWALL, PAINT HOLDING WATER AND UPSTAIRS FOUND A 3 FT X 8 FT SECTION OF CEILING DRYWALL REMOVED DUE TO THE AMOUNT OF WATER DAMAGE. ON THE ROOF I FOUND WATER PONDING IN BOTH THE S/E AND S/W CORNERS OF THE ROOF AROUND WHERE ROOF DRAINS WERE LOCATED, AND UNDER THE A/C UNIT. ROOF WAS CRACKED THROUGHOUT, ROOF COVERING WAS VERY SOFT, SPUNGY ALMOST AS IF 3-PLY ROOF COVERED A FOAM ROOF. WATER WAS CAUGHT UNDER THE ROOF COVERING AND OOZED OUT FROM UNDER THE TOP SHEET WHEN STEPPED UPON. I WAS ABLE TO RUB THE ROOF COVERING OFF WITH MY BOOT, SHOWING HOW SATURATED AND HOW MUCH WATER IS CAUGHT UNDER THE ROOF COVERING. |