Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T17DV02823

Parcel: 11105030F


Addresses:

3201 E PRESIDIO RD

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
06/28/2017 INSP - INITIAL CODE ENFORCMENT Approved INSPECTION FOUND A CAR HAD RUN INTO ONE OF FOUR BRICK COLLUMS IN THE FRONT OF THE CHURCH SCHOOL. THE COOLUMS APPEARED TO BEAR ONLY THE 6 FT SOFFIT, BUT NOT ACTUALLY A BEARING POINT FOR THE ROOF SYSTEM. THE COLLUM WAS 20" X 24" AND FILLED SOLID INSIDE ALSO WITH RED BRICK. THE COLLUM 11 FT IN HEIGHT LOST THE BOTTOM 8FT. THE TOP 3FT REMAINED IN PLACE AND WAS BRACED UNDERNEATH WITH TWO 4 X 4 POSTS UNTIL REPAIRS CAN BE COMPLETED. CAUTION TAPE WAS USED TO CLOSE OFF THE PORCH AREA.
VEHICLE HIT THE COLLUM EARLY MORNING WHEN NOBODY OCCUPIED THE BUILDING. WHEN PEOPLE ARRIVED AT APPROX 10 AM AND NOTICED THE COLLUM, TFD &TPD WERE CONTACTED AND CALLED C/E OUT LATER IN THE AFTERNOON.
FIELD NOV ISSUED FOR PERMITS REQUIRED.