Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T17DV02648
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2017 | INSP - INITIAL CODE ENFORCMENT | Approved | EMERGENCY CALL OUT BY TFD: FIRE DAMAGE TO THE SECOND FLOOR EXTERIOR STAIRCASE, STAIRCASE IS STEEL FRAME WITH CONCRETE STEPS., THERE IS FIRE DAMAGE TO A CROSS BEAM, ONE FLOOR JOIST AND THE WOOD MEMBERS IN THE STUCCO WOOD FRAMED COLUMN, ALSO SHEETROCK CUT OUT 2 X 2 AREA IN PATIO CEILING . THE FIRE WAS CAUSED BY WELDING TWO 3 INCH BY 10 FOOT STEEL POSTS WHICH HAVE BEEN INSTALLED TO SUPPORT THE STAIRCASE TO THE 2ND FLOOR, WHILE WELDING, SPARKS ENTERED THE STUCCO AND THE BEAM, ONE FLOOR JOIIST AND THE WOOD MEMBERS IN THE COLUMN WERE DAMAGED PROFESSIONAL ENGINEER REQUIRED FOR FIRE DAMAGE TO WOOD MEMBER AND THE INSTALL OF THE STEEL POSTS ADD TO SUPPORT THE 2ND STORY STAIRCASE LOAD. NOTE: THE STEEL POSTS HAVE BEEN WELDED AT ONE POINT AT EACH POST TO THE STEEL FRAME STAIRCASE, SEE PHOTOS IN SIRE |