Case: T17DV02180

Parcel: 111052580


Addresses:

3003 N ALVERNON WY


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T17DV02180

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
05/26/2017 INSP - INITIAL CODE ENFORCMENT Approved Received call from communication that T.F.D. on site with a apartment fire. Arrived and the units are still in the process of finding hot spots and doing the overhaul. The fire was on a upper unit and the water was going through the ceiling and flooding the unit. The fire started in the bedroom and went through the bathroom and started going into the livingroom. The unit has heavy smoke damage holes in the drywall in walls and ceilings to check for fire, a vent hole was cut in the roof and has trusses that will need to be check when cutting, the electrical was removed at the switch gear due to not able to find a panel to the unit. Did have a panel for the unit and not able to turn that off. The gas was turned off due to has a water heater in the attic area and not able to get to it and check and not sure what type of pilot the water heater has. The gas meter was pinned and once the water heater is checked, the gas can be turned back on. The unit has been condemned due to the fire damage and lacking utilities. The management is securing the unit. The fire units were called to the site due to finding smoke coming from the closet area and going into the attic area. Did do the posting of Do Not Enter and the manager signed the paperwork. The tenant was taken to the hospital and the kids are with another tenant on the property. While leaving the site the Redcross came to the site to check the unit that burned. Did have to call the police department to the site twice due to incidents on the property with people not living on the property. The manager will call when they get a hold of the electrician. Will check in 45 days RV.
05/26/2017 INSP - INITIAL CODE ENFORCMENT Approved Visited the site to try to determine how electric is fed to the building. This building has been installed with the old feed thru panels. It appears that the first panel has multiple taps for additional feeds to pass thru to the other units as per oringinal design. An Electrical Contractor will be needed to isolate the pass thrus's to be able to reenergize the unaffected units. Spoke to the owner and he will have the contractor call us. Owners electrician is on site doing the isolation taps.