Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
Case Number - T17DV00601
Inspection Description - INSP - FOLLOW UP CODE ENFORCE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2017 | INSP - FOLLOW UP CODE ENFORCE | Approved | FOLLOW UP INSPECTION FOUND ELECTRICAL ISSUES ABATED UNDER PERMIT T17CM01195. COMPLIANCE /CLOSE CASE. | |
03/08/2017 | INSP - FOLLOW UP CODE ENFORCE | Approved | VISITED SITE AFTER 1ST INSPECTION BY DSD WAS CONDUCTED. AGREEMENT WITH DSD WAS THAT 3 UNITS WERE ALLOWED POWER, THEN UPGRADED TO 5 UNITS. OUR INSPECTION TODAY FOUND POWER RESTORED TO AL UNITS AND EVERYBODY MOVED BACK INTO ALL UNITS. RICK HOLLANDER WENT TO VERIFY POWER ON THE EAST SIDE AND I MET WITH GLENN HIEDEMAN, THE OWNER. GLENN TRIED TO MAKE US UNDERSTAND THAT THE INSPECTOR CONDUCTING THE 1ST INSPECTION UNAWARE OF THE SITUATION GAVE CLEARANCE TO ENERGIZE ALL UNITS AND THEY COULD MOVE BACK IN. RICK HOLLANDER CONTACTED JIM BURGE THE INSPECTOR, ANGEL "BRO" THE ELECTRICIAN AND EMAILED CLAYTON TREVYLLAN.. I CONTACTED MARTIN ROMERO AND SPOKE TO THE TENANT IN UNIT 3 WHO WAS IRRATE. AFTER TALKING TO MARTIN ROMERO IT WAS AGREED THAT A DECISION WOULD NEED TO BE MADE BY CLAYTON PROBABLY NEXT DAY. | |
02/13/2017 | INSP - FOLLOW UP CODE ENFORCE | Approved | MET WITH ELECTRICAL CONTRACTOR ANGEL OF ENERGY SOURCE ELECTRIC AND OWNER GLENN H. FOUND ANGEL ALREADY MAKING MINOR REPAIRS IN THE STRUCTURES AND TO THE MAIN SERVICE PANEL I EXPLAINED THE TEP WIRE WAS UNDERSIZED FOR THE PANEL, THE PANEL WAS INSTALLED WITHOUT A PERMIT, PANEL WAS UNDERSIZED FOR TH E COMPLEX AND JUST ABPUT EVERY FUSE IN THE INTERIOR SUB PANELS KEPT POPPING EVIDNENCED BY THE NEW FUSES FOUND THRU OUT THE COMPLEX. I EXPLAINED HE NEEDED TO SPEAK WITH DAN SANTA CRUZ OF CLAYTON TREVILLYAN. ANGEL ASKED IF WE COULD MEET WITH BOTH OF THEM SO ANGEL, MYSELF AND THE OWNER DROVE TO DSD TO SPEAK WITH CLAYTON. DID MEET WITH DAN SANTA CRUZ WHO EXPLAINED BECAUSE OF THE AGE OF THE BUILDING, THE FACT IT WAS COMMERCIAL AND THE VARYING ELECTRICAL PROBLEMS, THAT A ARCHITECT AND ENGINEER WILL PROBABLY NEED TO GET INVOLVED AND DETERMINE LOAD CALCS AS WELL AS CONTACTING TEP TO DETERMINE WHAT WILL WORK, WHAT WON/T AND DAN SUGGESTED THEY GET WITH THE BUILDING OFFICIAL FIRST. CLAYTON WAS NOT IN AT THE TIME, AND ASKED IF THEY COULD WAIT. DAN SUGGESTED THEY MAKE AN APPOINTMENT. | |
02/12/2017 | INSP - FOLLOW UP CODE ENFORCE | Approved | SUNDAY F/U INSP MPLETELY.MOVING OUT PECTION FOUND ONLY UNIT 11 OCCUPANT ON THE PREMISES, SHE STATED SHE WAS ONLY COMPLETING THE MOVE. | |
02/11/2017 | INSP - FOLLOW UP CODE ENFORCE | Approved | FOLLOW UP INSPECTION PER RICK SALDATE FOUND OCCUPANTS IN UNIT 1,,3 6,7, 10, 11, AND 13 REMOVING CLOTHING AND OTHER BELONGINGS. OWNER GLENN HEIDEMAN WAS ALSO ON SITE MONITORING THE SITUATION. IT APPEARED THAT THERE WAS A LOT GOING ON. |