Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T17DV00573
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/08/2017 | INSP - INITIAL CODE ENFORCMENT | Approved | Emergency call-out from Tucson Fire and TPD house fire. Arrived on scene met with TPD officers still on site tenant of unit which is in the manager unit at a trailer park was arrested and put in for mental health evaluation. Fire involved the exterior wood fence around the front of the unit, no major damage to the fence and no damage to the main structure. TPD still had control of the unit was allowed in by them, noted front door was not able to be locked two broken windows at front of structure. In the interior first room was the living room exposed Romex at ceiling level not an issue however open junction boxes in living room and 1st bedroom along with missing faceplates to outlets at floor level. Moved into the kitchen stove was unplugged, under sink however there was no piping or trap so water was leaking on the floor. Moving into bedroom behind kitchen found again exposed wiring at ceiling level however exposed Outlets at floor level from there moved into restroom where I did see water leaking from the toilet. Owner stated toilet was not operational, and he was going to replace toilet a couple weeks ago however tenant chased maintenance off with a knife. Moving into the laundry room found wiring coming out of the wall not in junction box and not terminated correctly. Because of the Hazardous conditions with the electricity and the leaking plumbing in the kitchen and restroom power was shut off at Breakers to the structure and water valve was shut as well to stop further leaks in the interior. Because of lack of utilities this property will be condemned a notice of violation will be issued to property. Owner to repair the violations in the interior. Owner will also move to secure the broken windows in front as well as the front door and have an electrician remove the breakers to the structure all done today. TJ from maint on site and started working on front door, and will move to boarding windows. Met with office manager at owners place of business signed all my paperwork and copies were given, will do a more comprehensive NOV and mail it out to her. |