Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/21/2018 PLUMBING - FINAL Approved IVRS - Inspection :*
02/14/2018 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999


*
01/26/2018 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1- SHALL EXPOSE THE TRAP PRIMER IN WALL OR PROVIDE A TRAP GUARD FOR THE FLOOR DRAINS LOCATED IN THE MENS AND WOMENS RESTROOM.
2- SHALL PROVIDE 6 INCHES FROM THE TOP OF THE URINAL TO THE C/L CRITICAL LEVEL ON THE FLUSH VALVE DISCHARGE TUBE ON THE ACCESSIBLE URINAL.
12/21/2017 PLUMBING - FINAL Prior to Final Inspectn WATER CHLORINATION REPORT REQUIRED