Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T17CM09249
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2018 | ELECTRIC - FINAL | Approved | ||
| 07/12/2018 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* CLEAR ELECTRIC INCR |
|
| 07/10/2018 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE ADDRESS LABELS ATTACHED TO THE SERVICE METER BANK. 2- THE UFER GROUND CONDUCTOR CAN NOT BE CONNECTED TO THE EXISITING UFER WITH A SPLIT BOLT. GROUND CONDUCTOR SHALL BE CONTINUOUS. 3- SHALL PROVIDE A WATER BOND. * |
|
| 07/09/2018 | ELECTRIC - FINAL | Partial Approval | ORIGINAL APPROVAL 4/26/2018 BY DFLORES2. DID NOT INCLUDE 2ND IUNIT. RE-OPENING TO CALL INSPECTION FOR 2ND UNIT AND SEND CLEARANCE ONCE APPROVED. | |
| 03/20/2018 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- THE PLANS CALL FOR A ARRAY OF (32) MODULES. * |