Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2018 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 01/30/2018 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- REFERENCE SECTION 230.24 NEC 2011 FOR ABOVE ROOF CLEARANCE. * |
|
| 01/22/2018 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- RISER MAST IS LOCATED TO LOW TO THE ROOF. THE NEC REQUIRES IT TO BE LOCATED EIGHT FEET ABOVE THE ROOF WHEN THE CONDUCORS TRAVERSE THE ROOF. * |
|
| 01/10/2018 | ELECTRIC - SERVICE UPGRADE | Not ready for Inspection | IVRS - Inspection :* CLEAR ELECTRIC INCR |