Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/03/2018 | EXCAVATION/LAYOUT REBAR & ZON | Approved | ||
09/25/2018 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | MRI slab with 2 MATS OF 12" x 12" number five fiberglass rods, TIED WITH PLASTIC SNAP TIES | |
08/03/2018 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection 1- STEEL REINFORCEMENT IN FOOTING PROVIDED 2- THIS INSPECTION IS FOR THE FRONT ENTRANCE ONLY. |
|
07/17/2018 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1- SOUTH MAIN ENTRY WAY CONCRETE PRE SLAB IS OKAY FOR CONCRETE POUR. 2- PLUMBING RISERS HAVE BEEN PROTECTED. |
|
06/22/2018 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | OK TO POUR MAIN AREA UP TO WHERE CONTRACTOR SPECIFIED. | |
05/31/2018 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1- STEEL REINFORCEMENT IN FOOTINGS FOR THE LOADING DOCK AND GENERATOR PROVIDED. |