Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: STUCCO MESH
Permit Number - T17CM09083
Inspection Description - STUCCO MESH
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2018 | STUCCO MESH | Approved | ||
| 03/01/2018 | STUCCO MESH | Cancelled | ||
| 02/23/2018 | STUCCO MESH | Denied | 1 shim bearing headers 2 nail 2nd floor shear wall sole plates per shear schedule 3 block combustion vents in garage 4 install gble end braces per detail 306 5 install anchor bolts within 12" of plate end in garage n wall 6 seall all penetrations in lqth 7 provide access to ufer clamp 8 ground metql box in master bath 9 complete electric in attic, master bath and front edroom 10 protect electric conductors within 6' of attic access 11 complete line sets 12 install insulation shield on w/h b vent in attic 13 cripple a/c return in master |