Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T17CM08973
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/14/2018 | ELECTRIC - RECONNECT | Approved | APPROVED UNIT 806 AND 800 |
|
| 12/22/2017 | ELECTRIC - RECONNECT | Partial Approval | UNIT 818 IS OK TO RECONNECT RECN UNIT 800 DENIED, UNIT IS LOCKED UNIT 806 DENIED, BLUE CEILING J-BOX IS MISSING ROMEX CONNECTORS CEILING BOXES ARE MISSIMG COVERS WIRES ARE SPLICED TOGETHER THAT ARE NOT IN A J-BOX NO GROMMETS TO PROTECT WIRING AT CONDUIT CUTS. |
|
| 12/06/2017 | ELECTRIC - RECONNECT | Denied | UNIT 800 NO ACCES PANEL BOX INSIDE THE BUILDING SECURE ALL METAL BOXES PLUG ALL KNOCK-OUT HOLES SECURE WIRING TO EXIT SIGN NO ADDRESS ON FRONT OF BUILDING UNIT 806 LABEL PANEL BOX ON ACCES TO INSIDE OF BUILDING UNIT 818 MISSING DEAD FRONT IN PANEL BOX NO GFCI RECEPTACLES IN BATHROOM LABEL PANEL BOX MISSING ADDRESS IN FROMT OF BUILDING |