Permit: T17CM08682

Parcel: 141363220

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T17CM08682

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/16/2018 FRAMING Approved
01/12/2018 FRAMING Denied 1. FHA STRAP MAIN GAS RISER OVER-BORE, AND ABS TOP PLATE OVER BORE.
2. MOVE PEX 12" FROM CAN LIGHTS.
3. SUPPORT 4 GANG IN KITCHEN.
4. REDO GAS TEST. - 1.5 LBS AT PRESENT.
5.FINISH WIRING AT STOVE.
6. NEED RFI FROM ENGINEER FOR DRYER DUCT OVER-BORE IN 2X6 TOP PLATE OF SHEAR WALL.
7. NEED DWV AND WATER PRESSURE.
8. NAIL OFF FHA STRAP AT HVAC LINE OVER-BORE.
9. FINISH OUTLET WIRING IN N.E. AND N.W. BEDROOMS.
10. SCREW TOILET FLANGES TO FLOOR