Permit: T17CM08485

Parcel: 13418113D


Addresses:

7454 E BROADWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/21/2018 PLUMBING - INTERMEDIATE Approved
05/18/2018 PLUMBING - INTERMEDIATE Not ready for Inspection DWV not Under Test
05/16/2018 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE MISSION SPECIALTY COUPLINGS WHEN MAKING A TRANSISION CONNECTION OF DISSIMULAR MATERIALS ON THE DWV SYSTEM.
2- CAN NOT LOCATE A THRERADED FITTING IN A CONCEALED LOCATION.
3- WET VENTED SYSTEM FOR THE 2ND FLOOR WATER CLOSETS NOT PERMITTED. REFERENCE SEC TION 911.3 AND 912.1.1 2012 IPC.
4- SHALL PROVIDE RISER CLAMPS FOR ALL RISERS THROUGH THE 2ND FLOOR.
5- SHEET ROCK NAILING OKAY FOR TAPE AND MUD.


*