Permit: T17CM08190

Parcel: 133133680


Addresses:

7549 E BOOKMARK PL


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T17CM08190

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/16/2018 FRAMING Approved
02/13/2018 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL REPAIR THE VOID KNOCK OUT FOR THE GAS PENETRATION THRU THE FIRE BOLCKING AT THE RANGE.
2- SHALL SEAL ALL PENETRATIONS ALONG THE RANGE WALL.
3- EAST BATHROOM LAVATORY TRAP ARM HAS NEGATIVE PITCH.
4- PROVIDE DWV WATER TEST.
5- SOLE PLATE MISSING SEAT AT THE MASTER BEDROOM.


*