Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T17CM08117

Parcel: 14044018J


Addresses:

7440 S WILMOT RD


Inspection Status: Approved

Inspection History: ENGINEERING - FINAL

Permit Number - T17CM08117

Inspection Description - ENGINEERING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/13/2018 ENGINEERING - FINAL Approved
06/08/2018 ENGINEERING - FINAL Partial Approval OK FOR THE TCO AT THIS TIME, FINAL NOT TO BE GIVEN TILL ALL OF THE WORK ON THIS SITE ID COMPLETED PER THE APPROVED PLANS.
THE FOLLOWING ITEMS ARE NOT COMPLETED PER THE APPROVED PLANS AND WILL NEED ADDITIONAL WORK:
1) THE NORTHERN HANDICAP PARKING SPACE LOCATED ON THIS SITE IS OUTSIDE THE MAXIMUM COMPLAINCE FOR THE SLOPES. THE CONTRACTOR WILL BE WORKING ON MAKING THE NECESSARY CHANGES TO BRING IT BACK INTO COMPLIANCE PRIOR TO CALLING IN FOR RE INSPECTION.
2) ALSO THE RAMP COMING IN FROM WILMOT EXCEEDS THE MAXIMUM SLOPE ON THE SIDEWALK AND MAY REQUIRE THAT HANDRAIL BE PLACED ALONG THE OUTER EDGES OF THE RAMP ACCORDING TO ICC A117.1-2009 SECTION 405.8 HANDRAILS. I WILL DISCUSS THE OPTIONS WITH THE BUILDING OFFICIAL PRIOR TO MAKING THIS DETERMINATION.
3) COMPLETE THE TRASH ENCLOSURE TO BRING IT O THE PROPER HEIGHT OF 5.5 FEET ABOVE THE FINISH SLAB.
4) COMPLETE ALL OF THE PLACEMENT OF THE LANDSCAPING MATERIALS THROUGHOUT THIS SITE.