Inspection History: FRAMING
Permit Number - T17CM08095
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/03/2017 | FRAMING | Approved | ||
11/01/2017 | FRAMING | Denied | 1. FIRE BLOCK/ FIRE FOAM/ FIRE CAULK ALL HOLES IN TOP PLATES, DROP SOFFITS, AND FURRED WALL TOP PLATES. 2. STUD SHOE ALL OVER BORED BEARING STUDS AND FHA STRAP THE NON-BEARING ONES. 3. NEED DRYER VENT INSTALLED AND H2O HEATER TPR DRAIN LINE. 4. BLOCK ALL DUCT BOOTS 3 SIDES. 5. PEX CANNOT BE WITHIN 12" OF A CAN LIGHT. 6. SECURE TOILET FLANGE TO FLOOR. |