Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T17CM07524
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/12/2017 | PLUMBING - FINAL | Approved | APPROVED | |
10/05/2017 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL EXTEND AND TERMINATE THE WATER HEATER T & P DRAIN TO DAYLIGHT AND TERMINATE 6 INCHES ABOVE SUB GRADE. 2- SHALL PROVIDE A MINIMUM OF 10 X 10 INCHES LOUVER GRILL FOR COMBUSTION AIR LOCATED 12 INCHES BELOW CEILING ENCLOSURE. * |